The statistics of the image values within the defined VOIs can be calculated with the Statistics multi-function button.

The following VOIs are considered in the statistics:

Statistics Numbers

Statistics calculates simple statistical information for all the VOIs and presents them in a dialog window.

For each VOI the following pixel statistics is calculated.

AVERAGED

Average of all VOI pixel values.

SD

Standard deviation of all VOI pixel values.

VOLUME

Volume of all VOI pixel values.

TOTAL(SUM)

Sum of all VOI pixel values. The interpretation depends on the image contents. In the case of activity units the result will be total activity in the VOI.

TOTAL(AVR*VOL)

Average of all VOI pixel values multiplied by their volume. The interpretation depends on the image contents. In the case of activity concentration units, the result represents total activity in the VOI.

In the case of SUV units, the result is called Total Lesion Glycolysis (TLG). The TLG is usually calculated in combination with a lower range.

MINIMAL

Minimum of all pixel values.

MAXIMAL

Maximum of all pixel values.

NUMBER_OF_POINTS

Number of pixels in the VOI.

HOT_PIXELS_AVERAGED

After sorting the VOI pixel values in decreasing order, average of the highest Number of Hottest Pixels values. The default number (specified in the configuration) can be changed in the upper part of the dialog.

Note: The statistics are always calculated using the raw image pixel values, even when the images are shown with smoothing/interpolation enabled. Only full pixels are considered, no partial pixel areas are taken into account. Please enable the Fill ROI box to see which pixels are included in the statistics.

Note the Calculate in Range box which allows restricting the statistics to the subset of pixels with values in a specific range. For example, by setting the lower threshold to 40% of the maximum it is possible to calculate the average value and the volume of all pixels above 40%. The statistics numbers selected in the Selected for Save area can be saved into a new text file using Save, or appended to an existing one using Append.

Multi-Statistics and Pixel-Dump

The button Multi Statistics allows applying the same statistics to a set of files in a batch mode operation. After activating Multi Statistics a dialog window appears for selecting the VOIs of interest and the files to be processed.

After activating Save, PMOD will prompt for a result file, and the calculations will be started.

The button Pixel Dump allows dumping the coordinates and values of all pixels in the VOIs to a text file which can later be opened and analyzed in a dedicated statistics program. The files contain columns with the file name, patient name, VOI name, acquisition time, x, y, z, and the pixel value. The same information can be extracted from a batch of files using the Multi - Pixel Dump button.